MIT «DIALYSER» VERWANDTE WÖRTER IM WÖRTERBUCH ENGLISCH
dialyser
reactions
manufacturers
reuse
reprocessing
machine
system
membrane
surface
area
medicine
dialysis
process
removing
waste
excess
water
from
blood
used
primarily
which
choose
introduction
exchanges
through
membranes
removal
uraemic
solutes
that
retained
because
urea
dialysers
filters
fresenius
medical
care
ments
components
including
helixone®
improved
diffusive
convective
clearances
refined
haemodynamics
elisio
high
flux
nipro
australia
dialyser
product
info
next
generation
performance
friendly
long
been
recognised
europe
sureflux®
dialyzer
excellent
small
molecules
10 BÜCHER, DIE MIT «DIALYSER» IM ZUSAMMENHANG STEHEN
Entdecke den Gebrauch von
dialyser in der folgenden bibliographischen Auswahl. Bücher, die mit
dialyser im Zusammenhang stehen und kurze Auszüge derselben, um seinen Gebrauch in der Literatur kontextbezogen darzustellen.
1
Replacement of Renal Function by Dialysis: A Text Book of ...
Stationary coil dialyser with cellophane tubing wrapped between a long strip with
vertical stainless steel rods, constructed by Bodo von Garrelts, Stockholm,
Sweden in 1947 (54). The surface area was later enlarged to 1.92m2; blood
volume ...
THE DEVELOPMENT OF THE DIALYSER Jack Leonards and Leonard Skeggs
produced a plate dialyser that would permit a reduction in the priming volume
and allow negative pressure to be used to remove fluid from the patient's system
...
3
Chemical handicraft: a classified and descriptive catalogue ...
The Dialyser being prepared, the liquid to be operated upon is to be put into it, to
the depth of not more than half an inch, and the Dialyser is then to be floated on
distilled water contained in a flat basin. The quantity of the water in the basin ...
John Joseph Griffin, Cole Collection of Chemistry, 1866
4
The Great Ormond Street Hospital Manual of Children's ...
Place the dialyser in the holder. Connect the arterial line to 7. To assemble the
circuit and dialyser and place correctly the arterial (red) end of the dialyser.
Clamp the patient end on the machine. Always refer to manufacturer's of the line
and ...
Susan Macqueen, Elizabeth Bruce, Faith Gibson, 2012
5
Nephrology, hypertension, dialysis, transplantation
Biocompatibility, size of removed particles, possibility of sterilisation mode are
mainly determined by the dialysis membrane, all other aspects of effective
dialysis are related to the design of a dialyser. Current dialysers are available
only as ...
Thomas E. Andreoli, László Rosivall, Eberhard Ritz, 2006
6
Oxford Handbook of Dialysis
Dialyser KoA The larger the KoA, the greater the clearance of urea achievable in
a given time, and the more expensive the dialyser. High KoA dialysers may be
associated with more acetate-related side effects in units still using acetate
buffers ...
Edwina Brown, Christine Daley, 2009
The biocompatibility of a dialyser is defined by the extent to which it activates a
number of biological systems including the complement, coagulation, and
Kallikrein systems. Older cellulose based dialyzers were shown to activate
complement ...
Bradley A Warady, Franz Schaefer, Steven R. Alexander, 2012
8
Oxford Handbook of Nephrology and Hypertension
Principle Blood is removed from the patient, anticoagulated, pumped through a
dialyser, and then returned to the patient (see Fig. 4.3). Within the dialyser, blood
and dialysate (flowing in opposite directions) are separated by a semi-permeable
...
Simon Steddon, Alistair Chesser, Neil Ashman, 2014
9
General Nursing - Medical and Surgical Textbook
Table 14.9 Process of haemodialysis (continued) Component Action Dialysate '
Blood Dialysate Coil dialyser Dialysate -'_"i>* — Dialysate Blood Hollow-fibre
dialyser Heparinised blood flows in one direction in the dialyser while the
dialysate ...
M.J. Viljoen, L.R. Uys, 1989
10
Management of Acute Kidney Problems
7.2.3 The basic dialysis fluid pathway through the dialyser. A = acid concentrate,
B = bicarbonate concentrate, UF Pump = ultrafiltration pump HeatingHeating
HeatHeat ExchangerExchanger De-aeration De-aeration and mixing and mixing
...
Achim Jörres, Claudio Ronco, John A. Kellum, 2010
10 NACHRICHTEN, IN DENEN DER BEGRIFF «DIALYSER» VORKOMMT
Erfahre, worüber man in den einheimischen und internationalen Medien spricht und wie der Begriff
dialyser im Kontext der folgenden Nachrichten gebraucht wird.
Automated Handling of Uneven Stacks at Fresenius Medical Care …
The dialyser production line at its plant at L'Arbresle, in east-central France, is equipped with a robot. "In 2009 we decided to automate our ... «ThomasNet News, Jun 15»
Indian researchers develop affordable 'artificial kidney'
“Due to this, each dialyser costs Rs1,000 (Dh59) to Rs1,500 (Dh88) and ideally three such dialysers are needed per week for each patient,” he ... «gulfnews.com, Mär 15»
Quanta SC+ Hemodialysis System for In-Clinic or At-Home …
Load the single-use disposable cartridge and connect to the dialyser, concentrates and blood lines. After automatic priming the system is ready ... «Medgadget.com, Jan 15»
Free dialysis for patients with Hepatitis B, C: HOTC
He, however, said that such patients will have buy dialyser, needles, fluids and medication on their own. “We are ready to provide free services ... «E Kantipur, Dez 14»
The best Christmas present? An NHS with no funding issues
The first time, his blood was so full of toxins when it went into the dialyser it was black, but that night he came round and we knew he was going ... «The Guardian, Dez 14»
Patients probably contracted Hepatitis C at Stanley Hospital: report
“Dialyser reuse is scientifically accepted,” the report states, but in its recommendations, it says minimising the number of reuses or not reusing ... «The Hindu, Nov 14»
Successful delivery of chemotherapy to treat small-cell prostate …
Adjustments to the patient's haemodialysis prescription included the use of high flux, a larger dialyser surface area and an increased dialysis ... «UroToday, Sep 14»
Increasing trend of kidney disease in Seychelles - new hemodialysis …
An artery and vein are selected by the doctor for the "arterio-venus fistula" needle and dirty blood is extracted by a dialyser, performing the ... «Seychelles News Agency, Sep 14»
High Dose HD associated with improved outcomes
The feasibility of multiple use of the same dialyser on the same patient was also established. In a second prospective, single-arm clinical study ... «Irish Medical Times, Aug 14»
Baxter Presents Efficacy and Safety Data on VIVIA Haemodialysis …
The feasibility of multiple use of the same dialyser on the same patient ... Due in part to multiple uses of its dialyser and blood set, the VIVIA HD ... «MarketWatch, Jun 14»