10 BÜCHER, DIE MIT «MEGOHM» IM ZUSAMMENHANG STEHEN
Entdecke den Gebrauch von
megohm in der folgenden bibliographischen Auswahl. Bücher, die mit
megohm im Zusammenhang stehen und kurze Auszüge derselben, um seinen Gebrauch in der Literatur kontextbezogen darzustellen.
1
L.S.A., List of C.F.R. Sections Affected
(iii) The dc bridge type megohmmeter. which may be alternating cur— rent (ac)
powered, shall have scales and multiplier which make it possible to accurately
read IR from 1 megohm to 1 gigohm. The voltage applied to the conductors under
...
2
The Code of Federal Regulations of the United States of America
(III) The dc bridge type megohm- meter, which may be alternating current (ac)
powered, shall have scales and multiplier which make it possible to accurately
read IR from 1 megohm to 1 gigohm. The voltage applied to the conductors under
test ...
Office of the Federal Register (U.S.) Staff,
2004
3
34 CFR Education: CFR Parts 300-399
(iii) The dc bridge type megohmmeter, which may be alternating current (ac)
powered, shall have scales and multiplier which make it possible to accurately
read IR from 1 megohm to 1 gigohm. The voltage applied to the conductors under
test ...
Office of The Federal Register,
2013
4
Precision Measurement and Calibration: Electricity: low ...
The accuracy of setting the Wolff potentiometer with 20 and 50 kv across the
resistor was within 10 ppm, i.e., the same as when the 100-megohm resistor was
shorted. With 100 kv across the resistor this accuracy was estimated as within 20
...
5
Investigation of Fixed High
Megohm Resistors
The development work was concerned with high stability high-megohm resistors and with high temperature normal resistance range resistors.
SPRAGUE ELECTRIC CO NORTH ADAMS MA.,
1951
6
Electricity--low Frequency
This was to make connections at every fifth brass elbow (every 10th resistor unit)
so that the 100-megohm standard could be divided into 10 sections of 10-
megohm units. These 10 sections were then connected in parallel and measured
as a ...
F. L. Hermach, R. F. Dziuba,
1968
7
U.S. Forest Service research note FPL
1,000 ohms 10 K. ohms 100 K. ohms 1,000 ohms 1,000 ohms 1,000 ohms 1,000
ohms 1,000 ohms See text and table 1 See text and table 1 1,000 ohms 1,000
ohms 1,000 ohms See text and table 1 100 K. ohms 1 megohm 1 megohm 1 ...
Forest Products Laboratory (U.S.),
1967
8
DS, GS, and Depot Maintenance Manual: Attitude-heading ...
2-5). (2) Set CONTROLLER switch S7 to 1, and DC VOLTMETER switch S5 to 1. (
3) Set the controller mode selector switch to COMP. The AN/USM- 98 should
indicate at least 1 megohm. (4) Set the controller mode selector switch to
SLAVED.
9
High Frequency Measurements and Noise in Electronic Circuits
Typically the RC probe tip network might be approximately a 9 megohm resistor
in parallel with a l2 pF capacitor. A typical scope load would be one megohm in
parallel with 20 pF. The probe cable is of a special design. The characteristic ...
10
International Critical Tables of Numerical Data, Physics, ...
Elongation, % Electric strength (v/mm) alternating current Resistivity (megohm-
cm) X 10« Dielectric constant at radio frequencies Water absorption (%) (24 hr at
50°) Dielectric constant for alternate ing current Temperature coefficient range (0
...
Edward Wight Washburn,
1927
10 NACHRICHTEN, IN DENEN DER BEGRIFF «MEGOHM» VORKOMMT
Erfahre, worüber man in den einheimischen und internationalen Medien spricht und wie der Begriff
megohm im Kontext der folgenden Nachrichten gebraucht wird.
PM and PdM for electric motors
... and the winding condition is assessed based on the megohm value obtained in the test; a stator winding insulation resistance value of zero ... «Plant Services, Mai 15»
Lab Utilities Help Promote Science
Most lab facilities are looking for sources of ultrapure (18.2 Megohm) water systems. These facilities want their ultrapure water system to be fed ... «R & D Magazine, Apr 15»
Crane Song Syren Mic Pre and Falcon Compressor
There are: a ¼-inch 1.2-megohm Hi-Z input jack, Mic/DI switch, a 24dB per octave 90Hz highpass filter, polarity reversal, +48-volt phantom ... «MIX, Feb 15»
Oscilloscope Mistakes, Part 2
Voltage response of a POL regulator to a step load using a 50-Ohm coax cable connection terminated into 50 Ohms and into 1 MegOhm. «EE Times, Sep 13»
Application-Specific Resins Purify Lab Water
The different grades of mixed bed resins and the respective water quality produced include: nuclear grade >15 megohm, semiconductor grade ... «Laboratory Equipment, Sep 13»
Polymer film generates mechanical energy just by getting wet
This piezoelectric actuator generated about 1.0V with a 10-megohm resistor in the circuit. Capturing that motion-induced voltage in a different ... «Ars Technica, Jan 13»
Teen electrocuted while working on unplugged computer
... said capacity, across the human skin with an _extremely conservative_ resistance of at least 100kohms (more likely in the megohm range)) doesn't add up. «CNET, Okt 12»
New Technology Aimed at Reducing Silica Contamination
The analyzer provides a warning when sample resistivity drops below 15 megohm-cm as measured at the instrument's conductivity cell and ; the analyzer shifts ... «Water World, Jul 12»
Energetic developments
... impedance, phase angle and capacitance, coil, DC step voltage, winding resistance, megohm, DC Hipot, surge and DC bar-to-bar armature ... «The Engineer, Mär 12»
Pure Lab Water Systems Should Be Simple
We also offer traditional water purification systems, which produce 18.2 megohm ultra-pure water, pure water and reverse osmosis water.". «Laboratory Equipment, Mär 12»