10 ENGLISH BOOKS RELATING TO «ACTINOMETRY»
Discover the use of
actinometry in the following bibliographical selection. Books relating to
actinometry and brief extracts from same to provide context of its use in English literature.
For ex- ample, in addition to optical actinometry, the concentration of fluorine
atoms in Refs.9 and 10 was determined independently by the titration method in
which CO2 was added to the initial gas mixture CF4/O2 and as a result of rapid ...
A. A. Ovsyannikov, M. F. Zhukov, 2000
2
Inactivation of Pathogens with Innovative UV Technologies
INCIDENT. IRRADIANCE. MEASUREMENTS. WITH. KI/KIO3. ACTINOMETRY.
Prepared by James R. Bolton and Mihaela I. Stefan2 Bolton Photosciences Inc.
628 Cheriton Cres., NW, Edmonton, AB, Canada T6R 2M5 Tel: 780-439-4709;
Fax: ...
3
Drugs, Photochemistry and Photostability
G. Favaro Dipartimento di Chimica Universita di Perugia via Elce di Sotto 8, 1-
06123 Perugia, Italy 1 INTRODUCTION The aim of this report on actinometry is to
meet the widespread demand of obtaining objective criteria which could be ...
Angelo Albini, Elisa Fasani, Royal Society of Chemistry (Great Britain), 1998
Actinometry is the procedure to standardise light sources, because for the
determination of quantum yields, knowledge of light flux, I0, i.e., number of
quanta falling per unit time, is required. A thermopile may be used for an absolute
calibration ...
5
Progress in Wastewater Disinfection Technology: Proceedings ...
Actinometry dosages. on the other hand. showed only an increase of
approximately l.6 times. Actinometry dosages provide a measure of the total
number of photons emitted 'by the lamps per unit volume and time. This dose is
directly related ...
6
Pharmaceutical Photostability and Stabilization Technology
Chemical. Actinometry. Günter Gauglitz Institut für Physikalische und
Theoretische Chemie, Universität Tübingen, Tübingen, Germany Stephan M.
Hubig Department of Chemistry, University of Houston, Houston, Texas, U.S.A. ...
Joseph T. Piechocki, Karl Thoma, 2006
7
Electrogenerated Chemiluminescence
Laser Intensity Measurement by Chemical Actinometry. A photooxygeneration
Actinometer. J. Phys. Chem. 80:2248–2253, 1976. eHD Brauer, W Drews, R.
Gauglitz, S Hubig. Heterocoerdianthrone: a new actinometer for the visible (400–
580 ...
8
Disinfection Efficiency and Dose Measurement of ...
This was tested by comparatively evaluating the degradation products of the
uridine actinometry under LP-, MP-, and P-UV exposure. The results from these
tests are presented below. Other variance in the dose measurement with the
pulsed ...
9
Issues in Chemical Engineering and other Chemistry ...
successful actinometers for the visible range Research findings, 'The potential of
AB(1F) systems for direct actinometry. Diarylethenes as successful actinometers
for the visible range,' are discussed in a new report. “A new actinometric ...
10
Optical Diagnostics for Thin Film Processing
6.3.1.1 Actinometry and Density Calibration Optical emission intensities reflect
excited-state densities, which are often a small and variable fraction of the
ground-state density. While this uncertainty does not affect the use of OES as a
real-time ...