10 ENGLISH BOOKS RELATING TO «CRYOCABLE»
Discover the use of
cryocable in the following bibliographical selection. Books relating to
cryocable and brief extracts from same to provide context of its use in English literature.
The cryocable comes to town American engineers are pressing on with a "half-
way" solution to the problem of piping power underground into city centres. Their
design, based on a liquid nitrogen cooled aluminium cable, has been rejected by
...
2
Applications of High Temperature Superconductors to Electric ...
This section discusses issues relating to manufacturing of cryocable and HTS
cables. 9.5.1. Resistive. Cryogenic. Cable. The cryocable with its aluminum
conductor is easiest to manufacture as it can use existing cabling machinery.
However ...
This paper describes studies conducted on a method to maintain the thermally
insulated cryocable in vacuum insulation, using adsorbents, and the results
obtained. Analysis of outgassing from thermal insulation materials was
conducted ...
4
Underground Power Transmission: The Science, Technology, and ...
For a firm rating (one circuit out of use) of, say, 500 MVA all cable systems —
except the VI-LN2 cryocable — require the installation of 2 X 500 MVA circuits.
Refrigeration boosting by the expediency of evaporating LN2 from storage tanks
at ...
Until recently, the highest demonstrated underground power transmission
capacity by a cryocable was 38 MVA, achieved by Hitachi Cable Co., Japan. It
has now been advanced to 240 MVA in tests carried out at the Massachusetts
Institute of ...
HIGH POWER TRANSMISSION TESTS OF SHORT VI-LN2 CRYOCABLE LOOP*
Peter Graneau Lewis B. Thompson, Jr. Mitchell O. Hoenig Underground Power
Corp. Vacuum Barrier Corporation Massachusetts Institute of Technology 586 ...
Institute of Electrical and Electronics Engineers. Electron Devices Group, 1976
7
Microwave Superconductivity
The ideal cryocable must present a large thermal impedance without adding
significant RF loss, which would degrade the system noise figure. Commercially
available 0.047 inch diameter stainless steel coaxial cable with reduced
thickness ...
H. Weinstock, Martin Nisenoff, 2001
Both visual observation and photography of discharges are possible through the
Pyrex window assembly (11). The vacuum pump is connected to the port (12).
Figure 4 is a photograph of the cryocable loop. Aluminum tube busbars are seen
to ...
Studies of Vacuum Sealed Cryocables for Superconductive line Using
Adsorbents K. Funaki In order to maintain stabilized cooling for a
superconductive coaxial cable, it is necessary to maintain a thermal insulated
cryocable in high vacuum ...
The cryocable comes to town American engineers are pressing on with a "half-
way" solution to the problem of piping power underground into city centres. Their
design, based on a liquid nitrogen cooled aluminium cable, has been rejected by
...