अंग्रेज़ी किताबें जो «WET-BULB THERMOMETER» से संबंधित हैं
निम्नलिखित ग्रंथसूची चयनों में
wet-bulb thermometer का उपयोग पता करें।
wet-bulb thermometer aसे संबंधित किताबें और अंग्रेज़ी साहित्य में उसके उपयोग का संदर्भ प्रदान करने वाले उनके संक्षिप्त सार।.
1
Basic Refrigeration and Air Conditioning
humidity is less than 100%, some evaporation will take place from the wet wick of
the wet-bulb thermometer. This evaporation of water from the wick cools the wick
and the bulb. Thus, the wet-bulb thermometer shows a lower reading than the ...
P. N. Ananthanarayanan, 2013
2
Camping & Wilderness Survival: The Ultimate Outdoors Book
The temperature indicated by the wet bulb thermometer is less than the
temperature indicated by a normal thermometer. The rate of evaporation from the
wet-bulb thermometer depends on the humidity of the air-evaporation and is
slower ...
3
Refrigeration & Air Conditioning Technology
The reading from a wet-bulb thermometer takes into account the moisture content
of the air. It reflects the total heat content of air. The wet-bulb thermometer will get
cooler than the dry-bulb thermometer because of the evaporation of the ...
William C. Whitman, William M. Johnson, John A. Tomczyk, 2005
It consists of a dry bulb thermometer and a wet bulb thermometer. The instrument
can be whirled around in the air to provide sufficient flow of air-water vapor
mixture over the two thermometers. The bulb of one of the thermometers, the dry
bulb ...
5
Thermodynamics and Thermal Engineering
The wet bulb temperature is generally marked as fwb. For measuring dry bulb
temperature, a plain thermometer is mounted in the humid air as show in Fig.
14.1 whereas in order to measure wet bulb temperature, the wet bulb
thermometer has ...
6
An introduction to thermodynamics
Air Dry-bulb thermometer Wet fabric Wet-bulb thermometer Air Fan Fig. 10.6 A
simple psychrometer A schematic diagram of a simple psychrometer (dry-bulb
and wet-bulb thermometer) is shown in Fig. (10.6). A wick which is always ...
wet-bulb thermometer, (0) radiation, (d ,the size, shape, material and wetting of
the wic , (e) the relative position of the dry- and wet-bulb thermometcrs, and (f) the
temperature and purity of the water used to wet the wick. A discussion of these ...
Roscoe L. Bloss, Mary J. Orloski, 1972
A simple psychrometer consists of two ordinary thermometers, as shown in
Figure 12-2; the bulb surface of one of the thermometers (the dry bulb
thermometer) is dry while the other thermometer bulb (the wet bulb thermometer)
is wetted by ...
Sanford Klein, Gregory Nellis, 2011
9
Postharvest Technology of Horticultural Crops
0.5oF if it is used in conjunction with a wet- bulb thermometer for determining
cold storage air conditions. The thermometer should be shielded from radiant
heat sources such as motors, lights, external walls, and people. This can be done
by ...
10
Precision Measurement and Calibration: Mechanics, R. L. ...
wet-bulb thermometer, (c) radiation, (d), the size, shape, material and wetting of
the wick, (e) the relative position of the dry- and wet-bulb thermometers, and (f)
the temperature and purity of the water used to wet the wick. A discussion of
these ...
«WET-BULB THERMOMETER» पद को शामिल करने वाली समाचार सामग्रियां
इसका पता लगाएं कि राष्ट्रीय और अंतर्राष्ट्रीय प्रेस ने निम्नलिखित समाचार सामग्रियों के बारे में क्या चर्चा की है और इस संदर्भ में
wet-bulb thermometer पद का कैसे उपयोग किया है।
Build a Homemade Incubator
The humidity, measured with a wet-bulb thermometer, will ideally start at 85 degrees Fahrenheit and then rise toward 90 degrees Fahrenheit during the last few ... «Mother Earth News, जनवरी 09»