FIGURE 1 Schematic of one chamber grid of a hemocytometer with Neubauer
ruling. When the coverslip is positioned correctly, the volume of liquid over each
square (subgrid) is a known constant, 0.1mm3 or 1.0 ¥ 10-4mL. If cells are
counted ...
2
Graff's Textbook of Routine Urinalysis and Body Fluids
Although automated cell counters are continually improving (see Chapter 14),
most cell counts are still performed manually using the hemocytometer. The most
common hemocytometer used is the Neubauer hemocytometer. As shown in ...
Lillian A. Mundt, Kristy Shanahan, 2010
3
Clinical Hematology: Theory and Procedures
A diluted specimen is added to a hemocytometer for manual enumeration of
erythrocytes in special circumstances, e.g., body fluids. Specimen Anticoagulated
whole blood or free-flowing capillary blood can be used. EDTA is the preferred ...
Mary Louise Turgeon, 2005
4
Tissue Culture Techniques: An Introduction
Hemocytometer Design and calculations Because all culture laboratories should
have a microscope available, cell counting with a hemocytometer is a simple task
. The hemocytometer is basically a slide with grid lines (counting chambers) ...
5
Practical Flow Cytometry
Before counters became available, people did cell counts by examining diluted
blood (or another cell sample) in a hemocytometer under a microscope. A
hemocytometer is a specially designed microscope slide with a ruled grid that
defines ...
6
Experimental Phycology: A Laboratory Manual
Denser cultures of smaller cells are best counted with a hemocytometer.
Regardless of which slide you choose, use a Pasteur pipette to bubble the
sample and mix it. Follow the instructions that are specific to your chamber.
Hemocytometer 1.
Christopher S. Lobban, David J. Chapman, Bruno P. Kremer, 1988
7
Clinical Pathology for the Veterinary Team
If a rocker is not available, be sure to mix the reservoir gently 10–15 times just
before charging the hemocytometer (Figure 2.8g). 8. Remove the pipette and
seat the hub back into the reservoir. 9. Just before placing the tip of the pipette
into the ...
Andrew J. Rosenfeld, Sharon M. Dial, 2011
8
Developmental and Reproductive Toxicology: A Practical Approach
3) Manual Sperm and Spermatid Counts Loading the Hemocytometer — Manual
concentration analysis is conducted by producing a homogenate of standard
volume from a cauda epididymis or testis sample of known weight and counting
the ...
Ronald D. Hood, Ronald D Hood, 2005
9
METHODS IN CELL BIOLOGY,VOLUME 11, YEAST CELLS
V. Measuring the Number of Cells A. Hemocytometer Counts Total numbers of
cells can be determined by visual counts, using ahemocytometer. It seems to us,
however, that this method should be used only when superior alternatives are ...
10
Methods of Tissue Engineering
Most common is the hemocytometer, which is versatile, efficient, accurate, and
inexpensive. HEMOCYTOMETER. The hemocytometer (counting chamber) is a
modified glass slide engraved with two counting grids of known areas (Fig. 4.1).
Anthony Atala, Robert Paul Lanza, 2002
用語«HEMOCYTOMETER»を含むニュース項目
国内外の報道機関が語った内容や、次のニュース項目の文脈から
hemocytometerという用語がどのように使われているかを調べてみましょう。
Cholangiocytes derived from human induced pluripotent stem cells …
The cells were then counted using a hemocytometer and fixed using 4% PFA for 20 min at 4 °C. Cell staining and flow cytometry analyses were performed as ... «Nature.com, 7月 15»
Rapid method for the isolation of mammalian sperm DNA
Sperm pellets were washed once, re-suspended, counted on a hemocytometer using the average of eight grid areas, and visually inspected for somatic cell ... «BioTechniques.com, 6月 15»
Development of genetic tools for Myceliophthora thermophila
... filtered through glass wool to remove residual mycelia and adjusted to 106 conidia per milliliter calculated using a hemocytometer. An aliquot ... «BMC Blogs Network, 5月 15»
Cell Counting Market Worth $8.6 Billion by 2020
According to a new market research report "Cell Counting Market by Product [(Instruments (Spectrophotometer, Cell Counter, Hemocytometer, ... «PR Newswire, 5月 15»
T cell expansion technology: an interview with Alexander Malykhin …
Currently, we are using either Trypan Blue staining with the hemocytometer and microscope or flow cytometry. It is time consuming method that ... «News-Medical.net, 5月 15»
Novel drug candidates for blast phase chronic myeloid leukemia …
Mononuclear cells were counted using a hemocytometer and suspended in mononuclear cell medium (PromoCell, Heidelberg, Germany) ... «Nature.com, 5月 15»
Transient elevation of glycolysis confers radio-resistance by …
The number of viable cells was counted on hemocytometer using trypan blue (0.4%) exclusion test and glucose consumption or lactate ... «BMC Blogs Network, 4月 15»
Idh1 protects murine hepatocytes from endotoxin-induced oxidative …
... an aliquot of freshly isolated hepatocytes was placed in a hemocytometer and stained with trypan blue to evaluate cell viability and determine ... «Nature.com, 4月 15»
Inorganic Arsenic-induced cellular transformation is coupled with …
Cell viability was determined by trypan blue dye exclusion using a hemocytometer and calculated as percent viability times total cells/ml. «BMC Blogs Network, 3月 15»
Using Beckman Coulter™ Multisizer™ 3 Coulter Counter® for …
... and also provides consistent results independent of the operator's judgment when compared to those obtained with a hemocytometer. «News-Medical.net, 11月 14»