アプリをダウンロードする
educalingo
raintight

"raintight"辞典での英語の意味

辞典

英語でRAINTIGHTの発音

ˈreɪnˌtaɪt


RAINTIGHTの文法範疇

名詞
形容詞
動詞
副詞
代名詞
前置詞
接続詞
限定詞
感嘆詞

RAINTIGHTと韻を踏む英語の単語

airtight · apatite · appetite · argentite · biotite · enstatite · haematite · hepatite · hydroxyapatite · hydroxylapatite · magnetite · pegmatite · piedmontite · piemontite · pyrrhotite · spessartite · stalactite · steatite · tennantite · watertight

RAINTIGHTのように始まる英語の単語

rainiest · rainily · raininess · rainless · rainmaker · rainmaking · rainout · rainproof · rains · rainspout · rainsquall · rainstick · rainstorm · rainswept · rainwash · rainwater · rainwater pipe · rainwear · rainy · rainy day

RAINTIGHTのように終わる英語の単語

bright · copyright · eight · fight · finger tight · gastight · hug-me-tight · lighttight · oiltight · overtight · sit tight · skintight · sleep tight · smoketight · steamtight · sticktight · supertight · tight · uptight · windtight

英語の同義語辞典にあるraintightの類義語と反意語

同義語

«raintight»を25ヵ国語で翻訳

翻訳家

RAINTIGHTの翻訳

当社の英語多言語翻訳者が翻訳した25ヵ国語raintightを探してみましょう。

自動統計翻訳によって、このセクションで示されている英語から他の言語へのraintightの翻訳を訳しました。この場合は、必須の翻訳単位は英語で«raintight»という単語です。
zh

英語翻訳家 - 中国語

raintight
1,325百万人のスピーカー
es

英語翻訳家 - スペイン語

prueba de lluvia
570百万人のスピーカー
en

英語

raintight
510百万人のスピーカー
hi

英語翻訳家 - ヒンディー語

raintight
380百万人のスピーカー
ar

英語翻訳家 - アラビア語

raintight
280百万人のスピーカー
ru

英語翻訳家 - ロシア語

raintight
278百万人のスピーカー
pt

英語翻訳家 - ポルトガル語

raintight
270百万人のスピーカー
bn

英語翻訳家 - ベンガル語

বৃষ্টি দ্বারা অভেদ্য
260百万人のスピーカー
fr

英語翻訳家 - フランス語

étanches à la pluie
220百万人のスピーカー
ms

英語翻訳家 - マレー語

Raintight
190百万人のスピーカー
de

英語翻訳家 - ドイツ語

raintight
180百万人のスピーカー
ja

英語翻訳家 - 日本語

raintight
130百万人のスピーカー
ko

英語翻訳家 - 韓国語

raintight
85百万人のスピーカー
jv

英語翻訳家 - ジャワ語

Raintight
85百万人のスピーカー
vi

英語翻訳家 - ベトナム語

không thấm mưa
80百万人のスピーカー
ta

英語翻訳家 - タミル語

raintight
75百万人のスピーカー
mr

英語翻訳家 - マラーティー語

दुलई
75百万人のスピーカー
tr

英語翻訳家 - トルコ語

raintight
70百万人のスピーカー
it

英語翻訳家 - イタリア語

tenuta di pioggia
65百万人のスピーカー
pl

英語翻訳家 - ポーランド語

raintight
50百万人のスピーカー
uk

英語翻訳家 - ウクライナ語

raintight
40百万人のスピーカー
ro

英語翻訳家 - ルーマニア語

raintight
30百万人のスピーカー
el

英語翻訳家 - ギリシャ語

raintight
15百万人のスピーカー
af

英語翻訳家 - アフリカーンス語

raintight
14百万人のスピーカー
sv

英語翻訳家 - スウェーデン語

raintight
10百万人のスピーカー
no

英語翻訳家 - ノルウェー語

raintight
5百万人のスピーカー

raintightの使用傾向

傾向

用語«RAINTIGHT»の使用傾向

raintightの一般的な使い方と傾向を主に検索します
英語オンライン辞典にアクセスする際に、ユーザーの主な検索リストと«raintight»で最も広く使用されている表現です。

英語文献、引用文、raintightに関するニュースでの使用例

例え

«RAINTIGHT»に関連する英語の本

以下の図書目録からraintightの使いかたを見つけましょう。raintightに関する本と英語文献で使われた文脈を提供するための簡単な抜粋文。
1
Electrical Wiring Residential
Raintight and Draining Outdoor locations are generally wet locations. However, under an overhang may be considered a damp rather than a wet location. If you are using EMT outdoors in a wet location, the fittings (couplings and connectors)  ...
Ray Mullin, Phil Simmons, 2011
2
NEC Q and A: Questions and Answers on the National ...
Question. 2.9. Are. goosenecks. permitted. to. be. located. below. service. drop. conductors? Keywords. Gooseneck Service head Weatherhead Service drop Raintight Point of attachment ...
Noel Williams, Jeffrey S. Sargent, 2007
3
Audel Guide to the 2011 National Electrical Code: All New ...
230.53: Raceways to Drain Serviceentrance raceways, when exposed to weather , shall be raintight and arranged todrain. Ifembedded in concrete theyshallalso be arranged to drain. A particular incident is worth mentioning here: A large ...
Paul Rosenberg, 2011
4
Interpreting the National Electrical Code
The previous edition of the Code required raceway to be raintight in wet locations . Most fittings suitable for use in wet locations are not listed as raintight. 225.27: Raceways entering a building or structure from an underground distribution ...
Truman Surbrook, Jonathan Althouse, 2011
5
NFPA's Pocket Electrical References
... prolonged submersion at a timited depth: and that will be undamaged by the external formation of ice on the enclosure Raintight; watertight Raintight; watertight; corrosion resistant Dri plight; dusttight Raintight; watertight Raintight: watertight; ...
Charles R. Miller, 2006
6
One and Two Family Dwellings 2008: Based on the NEC and ...
RAINTIGHT. SERVICE. HEAD. OR. GOOSENECK. 230.54(B). Service-entrance cable shall be installed in the form of a gooseneck and then taped and painted or plastic coated for protection from the weather. The entrance of rain through a ...
James G. Stallcup, James W. Stallcup, 2009
7
Taunton's Wiring Complete: Expert Advice from Start to Finish
Aboveground, electrical cable must be housed in conduit with raintight fittings ( see bottom photo at right). You can use polyvinyl chloride (PVC), thin-walled electrical metallic tubing (EMT) conduit, threaded intermediate metal conduit ( IMC) or ...
Michael W. Litchfield, Michael McAlister, 2008
8
Unit, Direct Support, and General Support Maintenance ...
6. Remove nut (9) and remove raintight connect (10). NOTE Before installing the replacement high-limit control (4), coat threads with thread sealer compound ( Item 5,AppC). 7. Install raintight connector (10) and nut (9) in high-limit control (4).
‎1992
9
Shale Shakers and Drilling Fluid Systems: Techniques and ...
1 General Purpose — Indoor 2 Driproof — Indoor 3 Dusttight, Raintight, Sleettight — Outdoor 3R Raintight, Sleet Resistant — Outdoor 3S Dusttight, Raintight, Sleettight— Outdoor 4 Watertight, Dusttight, Sleet Resistant — Indoor & Outdoor 4X ...
American Association of Drilling Engineers, 1999
10
Electrical Inspection Manual, 2014 Edition
Raintight Constructed or protected so that exposure to a beating rain will not result in the entrance of water under specied test conditions. [e term raintight is typically used in conjunction with enclosure Types 3, 3S, 3SX, 3X, 4, 4X, 6, and 6P.] ...
Noel Williams, Jeffrey S. Sargent, 2014

用語«RAINTIGHT»を含むニュース項目

国内外の報道機関が語った内容や、次のニュース項目の文脈からraintightという用語がどのように使われているかを調べてみましょう。
1
Building permits: Jan. 29 to Feb. 4
... 803 Crepe Myrtle Lane, install electric at new dwelling
  • Kenny Sims Electric, 14 Spring Valley Circle, replace bad raintight breaker box and breaker at ... «Longview News-Journal, 2月 15»
  • 2
    Center to reopen Tuesday after water damage
    Since it was indoors, there is no code requirement for watertight fittings on conduit systems, and the use of NEMA 3R (Raintight) equipment is not required either. «Tbo.com, 6月 14»
    3
    Emergency Lighting System suits hazardous locations.
    The CID2 is rated NEMA 3R (raintight), and is ruggedly built from compression molded, fiberglass reinforced polyester, formed with a continuous silicone gasket ... «ThomasNet News, 5月 14»
    4
    Raintight EMT Fittings require no disassembly. .
    ROSEMONT, IL – Raintight fittings are required by code to safely ground and attach EMT raceways to electrical junction boxes or enclosures in outdoor, damp ... «ThomasNet News, 3月 14»
    5
    Raintight Reducing Sealing Washers eliminate need for caulking.
    STRATFORD, Conn., - To help make a contractor's job easier and quicker, Bridgeport Fittings has introduced Mighty-Seal(TM) Raintight Reducing Sealing ... «ThomasNet Industrial News Room, 6月 12»
    6
    Crane & Boom Obstruction Lights - Solar LED
    The Model SLX-15 is raintight and offers two mounting options namely, permanent mounting with its (3) threaded studs on 1-¾" radius center, 120 degrees apart ... «ThomasNet Industrial News Room, 4月 12»
    7
    Conduit Couplings feature watertight seal.
    December 16, 2010 - Available in sizes from ½-4 in., 3-piece Mighty-Align(TM) Raintight Couplings have self-aligning design that ensures 360° watertight seal ... «ThomasNet Industrial News Room, 12月 10»
    8
    Raintight Fittings are available in steel and zinc.
    July 17, 2007 - UL-Listed EMT concrete-tight, raintight connectors feature split-type gland ring that prevents conduit from turning when tightening hex nut. Fittings ... «ThomasNet Industrial News Room, 7月 07»
    参照
    « EDUCALINGO. Raintight [オンライン] 利用可能<https://educalingo.com/ja/dic-en/raintight>. 6月 2026 ».
    educalingoアプリをダウンロードする
    JA