CĂRȚI ÎN ENGLEZĂ ÎN LEGĂTURĂ CU «RESPIROMETRIC»
Descoperă întrebuințarea
respirometric în următoarea selecție bibliografică. Cărți în legătură cu
respirometric și extrase din aceasta pentru a furniza contextul de întrebuințare al acestuia în literatura Engleză.
1
Toluene and Ethyl Acetate Biodegradation by Peat Biofilters: ...
Air streams discharged from industrial sources contain volatile organic compounds (VOCs) for which environmental regulations are being increasingly restrictive.
Javier Álvarez Hornos, 2008
2
Environmental Modeling: Proceedings of the International ...
The procedures are presented to estimate bio-kinetic parameters for
heterotrophic biomass. Respirometric analysis in the batch reactor was carried
out for the experimental assessment of kinetic parameters. To estimate bio-kinetic
parameters ...
Vijay P. Singh, Il Won Seo, Jung H. Sonu, 1999
3
Microbiology of Solid Waste
6.4.3 Respirometric Analysis Using Mixed Cultures The degree and rate of
biodegradation of synthetic polymeric materials can be determined using mixed
populations of microorganisms in screening level tests that rely on respirometric ...
Anna C. Palmisano, Morton A. Barlaz, 1996
4
Proceedings of the 49th Industrial Waste Conference Purdue ...
PRINCIPLES In this section the basics of the two respirometric principles that are
evaluated further are presented. The different approaches to calculate the BODsl
of the samples are illustrated with simulated raw data. General The short-term ...
5
On-line Continuous Aerobic Respirometry: A Real-time Study ...
Utilization of Respirometric Information Oxygen uptake studies have been vital to
development in the field of wastewater treatment field, aiding in facility design,
toxicity and acclimation assessment, kinetic parameter development, industrial ...
Jessica Nicole Keahey, 2008
6
Industrial, Medical and Environmental Applications of ...
Accumulated CO2 accumulated in respirometric systems after189 days of
biodegradation. A 78.595±6.3003 C 221.925±1.4778 D 188.485±6.3003 B5
225.390±43.5578 B10 227.645±36.0129 B50 265.045±9.7227 B100 413.875±
17.6565 by ...
Antonio Méndez-Vilas, 2014
7
Water & Wastewater Infrastructure: Energy Efficiency and ...
Online respirometric control has a theoretical advantage over traditional
automated dissolved oxygen control. Whereas DO is essentially an "after-the-fact
" analysis once the oxygen needs of the biomass have been met, OUR as
measured by ...
8
Produced Water: technological, environmental issues and ...
Petroleum hydrocarbon substrate removal measured and analyzed on the basis
of respirometric techniques, may be misleading due to abiotic removal
mechanisms, such as adsorption, volatilization, and chemical oxidation.
Therefore, testing ...
J. P. Ray, F. Rainer Engelhardt, 1992
9
Respirometric Analysis of Activated Sludge
The primary purpose of this study is the investigation of a wastewater treatment plant in terms of nitrogen removal potential and possible operational problems that may be generated by possible inhibitors.
10
Design and Operation of Activated Sludge Processes Using ...
This chapter will present four case studies that are representative examples of
applying the respirometric techniques and associated modeling methodologies.
Three of the case studies presented in this chapter relate the application and use
of ...
Alan Rozich, Anthony Gaudy, Jr., 1992
ȘTIRI NOI CARE INCLUD TERMENUL «RESPIROMETRIC»
Află ce ziare naționale și internaționale au scris despre și cum este întrebuințat termenul
respirometric în contextul următoarelor știri.
The Importance of Biochemical Oxygen Demand (BOD) in the Water …
The respirometric method (manometer) is based on the fact that the oxygen converted to carbon dioxide is removed from the gaseous spectrum via the sample ... «International Environmental Technology, Mai 15»
BOD - The Key Parameter of Water Treatment
A standard method is the respirometric method adapted from DIN 38 409-H52 / EN 1899-2. The BOD5 value is widely known where the demand of oxygen is ... «International Environmental Technology, Apr 15»
BODTrak II apparatus from Hach Pacific for simplified BOD analysis
The BODTrak II apparatus measures BOD using the respirometric method wherein each sample bottle is connected to a pressure sensor in a closed system. «Ferret, Aug 12»
Sensor paints herald new era of responsive materials
The effects were also shown to be useful for highly parallel screening of enzyme activities, to monitor respirometric activity, and in toxicological assays based on ... «Nanowerk LLC, Sep 08»
Humification and Degradability Evaluation During Composting of …
1996. Respirometric techniques in the context of compost stability assessment: principles and practice. In: de Bertoldi, P. Sequi, B. Lemmes and T. Papi (eds.). «RedOrbit, Iul 08»