КНИГИ НА АНГЛИЙСКИЙ ЯЗЫКЕ, ИМЕЮЩЕЕ ОТНОШЕНИЕ К СЛОВУ «CURIE-WEISS LAW»
Поиск случаев использования слова
Curie-Weiss law в следующих библиографических источниках. Книги, относящиеся к слову
Curie-Weiss law, и краткие выдержки из этих книг для получения представления о контексте использования этого слова в литературе на английский языке.
1
Solid-State Physics: An Introduction to Principles of ...
The Curie-Weiss law is experimentally fulfilled for T)T c .AsT c is approached,one
observes deviations from this law,and a better description is a decrease
proportional to (T±Tc)±4/3. According to our model the Curie- Weiss constant C is
...
Harald Ibach, Hans Lüth, 2009
2
Magnetic Materials: Fundamentals and Applications
5.2 The Curie–Weiss law In fact many paramagnetic materials do not obey the
Curie law which we just derived, but instead follow a more general temperature
dependence given by the Curie–Weiss law: χ = C T − θ . (5.16) Paramagnets
which ...
3
Frontiers of Ferroelectricity: A Special Issue of the ...
The solid line, fitted according to the Curie- Weiss law (1/K = (T−θ)/C, C is the
Curie constant, θ is the Curie-Weiss temperature) is valid far above TmTT (see
text). (from intercept) as a function offrequencies for BZT thin films with Zr
contents in ...
Sidney B. Lang, Helen L.W. Chan, 2007
4
Simulations for Solid State Physics: An Interactive Resource ...
Exercise 13.5 (M) Plot the inverse susceptibility Xn 1 versus T. From a distance it
looks like a good Curie-Weiss law. Close examination of very good data,
however, will show curvature of the plot at the lower temperatures. It may be
impossible ...
5
Introduction to Magnetism and Magnetic Materials, Second Edition
It should be remembered that the susceptibility only follows the Curie-Weiss law
in the paramagnetic region. Once the material becomes ordered the susceptibility
behaves in a very complicated way and no longer has a unique value for a ...
6
Textbook Of Engineering Physics
For Ni, Tc = 358°C; for Fe, Tc = 770°C; and for Co, Tc = 1120°C. According to
Curie-Weiss law: "Above Curie temperature, the magnetic susceptibility of a
ferromagnetic material is inversely proportional to (T - Tc), i.e. x = C/(T - Tc),
where C is ...
7
Spin Physics in Semiconductors
This gives the well-known Curie–Weiss law χMn = C/(T − θ), where the Curie–
Weiss temperature θ = λC is negative (positive) if dominant Mn– Mn interactions
are antiferromagnetic (ferromagnetic). Using the Heisenberg Hamil- tonian it is
very ...
Mikhail I. Dyakonov, 2008
8
Polar Oxides: Properties, Characterization, and Imaging
This behavior is achieved for temperatures large compared to Tf. At lower
temperatures, deviations from the Curie-Weiss law are attributed to strong local
magnetic correlations [8] and the onset of local (spin-glass) order below Tf.
Sherrington ...
Rainer Waser, Ulrich Böttger, Stephan Tiedke, 2006
9
Nitroxides: Applications in Chemistry, Biomedicine, and ...
1.3.3 The Curie–Weiss Law In reality the observed magnetic susceptibilities do
not obey the Curie law. This is because, in the above derivation of the Curie law,
we have assumed isolated magnetic moments and thus no magnetic interactions
...
Gertz I. Likhtenshtein, Jun Yamauchi, Shin'ichi Nakatsuji, 2008
10
Frontiers in Materials Physics, Vol. 1
0.04 and 0. 1 0 respectively. The fact that the departure from Curie- Weiss
behaviour is observed over a temperature range as large as 20 K for x = 0. 10
points towards a relaxor ferroelectric transition for which simple Curie- Weiss law
does not ...
НОВОСТИ, В КОТОРЫХ ВСТРЕЧАЕТСЯ ТЕРМИН «CURIE-WEISS LAW»
Здесь показано, как национальная и международная пресса использует термин
Curie-Weiss law в контексте приведенных ниже новостных статей.
A Review of Cryogenic Sensors for Emerging Applications
It applies the Curie-Weiss law for magnetic susceptibility. The paramagnetic susceptibility, χ, is inversely proportional to the temperature. «AZoSensors, Июл 14»