«PHOSPHOROSCOPE» İLE İLİŞKİLİ İNGILIZCE KİTAPLAR
phosphoroscope sözcüğünün kullanımını aşağıdaki kaynakça seçkisinde keşfedin.
phosphoroscope ile ilişkili kitaplar ve İngilizce edebiyattaki kullanımı ile ilgili bağlam sağlaması için küçük metinler.
1
Light Emission By Plants and Bacteria
B. Phosphoroscope According to the frequency selection principle discussed
above (Section I,B), the phosphoroscope method is of interest for the study of
relatively slow phenomena, when the envelope or average of the L emission is ...
2
Accuracy in Spectrophotometry and Luminescence Measurements: ...
... typical commercial phosphorimeter. A block diagram of a typical commercial
spectrophoto- fluorimeter with rotating can phosphoroscope which has been
used by the author (e.g., AMINCO SPF2 with phosphoroscope assembly) is
shown in ...
Radu Mavrodineanu, J. I. Schultz, Oscar Menis, 1973
In the Becquerel phosphoroscope the luminescent substance, is placed between
two disks which are mounted on a common axis and have sector shaped
apertures shifted with respect to each other by an angle. The exciting light enters
the ...
... be seen by the observer if it dragged any light along with it, for even the
thousandth of a second. FIG 1. BECQUEKEL'S PHOSPHOROSCOPE. A
contrivance for this purpose was made by Edmund Becquerel, and called the
phosphoroscope.
5
Analytical Instrumentation Handbook, Third Edition
C. Phosphorimeters Phosphorescence can be measured with a conventional,
continuous source fluorescence instrument that is equipped with a
phosphoroscope attachment. The phosphoroscope is used to eliminate
fluorescence signals on ...
6
Phosphorimetry: Theory, Instrumentation, and Applications
A phosphoroscope is a device which achieves this by allowing the measurement
of phosphorescence while the sample is being excited out of phase with the
measurement step. Several years ago the effects of phosphoroscope design in
the ...
Robert J. Hurtubise, 1990
7
Techniques and Methods in Biology
Figure 5.7 is a schematic diagram of rotating can phosphoroscope for
phosphorescence measurement. /- Sample cell Dewar flask with liquid nitrogen /
Phosphoroscope can To emission monochromator From excitation
monochromator ...
This can best be done by making use of a rotating shutter, called
phosphoroscope. The latter is used to introduce a definite delay between the time
intervals during which the sample is irradiated and observed. Several
commercial instruments ...
9
Fluorescence Lifetime Spectroscopy and Imaging: Principles ...
He is credited with building the first instrument (i.e., phosphoroscope) capable of
measuring time intervals as short as 10−4 s and pioneering the work in time-
resolved photoluminescence (Berezin and Achilefu 2010; Valeur and ...
Laura Marcu, Paul M. W. French, Daniel S. Elson, 2014
10
Instrumental Methods of Chemical Analysis
This can best be done by making use of a rotating shutter, called
phosphoroscope. The latter is used to introduce a definite delay between the time
intervals during which the sample is irradiated and observed. Several
commercial instruments ...