与 «AMPEROMETRIC»相关的英语书籍
在以下的参考文献中发现
amperometric的用法。与
amperometric相关的书籍以及同一来源的简短摘要提供其在 英语文献中的使用情境。
1
Wireless Microchip Capillary Electrophoresis Utilizing ...
The design and fabrication of a wireless chemical analyzing unit containing a pulsed amperometric electrochemical detection module, a 3-channel high-voltage power supply, embedded controller, modem and graphical user interface is described.
2
Pt-MWCNT and MWCNT Based
Amperometric Biosensors for Glucose ...
The work described in this research is centered on the development of a glucose-selective enzyme based amperometric sensor coupled with nanotubes as matrix materials.
Lavanya Aryasomayajula, 2008
3
Biosensors and Their Applications
Receptor Transducer Analyte References Glucose oxidase (GOD) Amperometric
Glucose 7-10, 14, 16-18,22,23, 25, 29, 32, 36-48 Glucose dehydrogenase (GDH)
Amperometric Glucose 38, 47, 49 Lactate oxidase (LOD) Amperometric Lactate ...
Victor C. Yang, That T. Ngo, 2000
4
Principles of Bacterial Detection: Biosensors, Recognition ...
2000). Electrochemical biosensors can be based on potentiometric,
amperometric, or conductrimetric transducers. In this chapter, amperometric
transducers will be described in detail. 2. Amperometric Biosensors L. C. Clark, Jr
., is generally ...
Mohammed Zourob, Sauna Elwary, Anthony P. F. Turner, 2008
5
Introduction to Polarography and Allied Techniques
AMPEROMETRIC. TITRATIONS. A conventional amperometric titration is one
whose course is followed by measuring a current—almost always a limiting
current at a voltammetric indicator electrode. Depending on the potential of the
electrode ...
6
Total and Free Chlorine Residual Analyzers Online ...
Instrumentation Testing Association (ITA) The three types of total and free
chlorine residual analyzers are • Amperometric titration or probe, • Colorimetric,
and • Oxidation-Reduction Potential (ORP) probe. Two other instruments that
measure ...
Instrumentation Testing Association, 1999
7
Self-assembling, Coiled Coil Interfaces for Nanoscale ...
Both gold nanostructures and carbon nanotubes are rapidly emerging platforms for amperometric biosensor detection.
Mark Ryan Contarino, 2008
8
Fundamentals of Biofilm Research, Second Edition
The limiting current in an amperometric sensor covered with a membrane is
described by I nFDCA P d lim bulk m = × (4.44) where Pm is the
permeability coefficient of the membrane and d is the thickness of the membrane.
4.1.3.4 ...
Zbigniew Lewandowski, Haluk Beyenal, 2013
9
13th International Conference on Biomedical Engineering: ...
Amperometric. Hydrogen. Peroxide. Sensors. with. Multivalent. Metal. Oxide-
Modified. Electrodes. for. Biomedical. Analysis. Tesfaye Waryo1'5'*, Petr Kotzian2
, Sabina Begic3, Petra Bradizlova2, Negussie Beyene4, Priscilla Baker5,
Boitumelo ...
Chwee Teck Lim, James Goh Cho Hong, 2009
10
Chemical Sensors and Biosensors: Fundamentals and Applications
Figure 14.16 Mechanism of an amperometric phenol sensor. ER and EO are the
reduced and oxidized forms, respectively, of the enzyme. Ph, Ph and Q are the
phenolic molecule, its phenoxy radical and its quinone form, respectively.
Adapted ...
Florinel-Gabriel Banica, 2012
包含词语«AMPEROMETRIC»的新条目
找出国内和国际出版社所讨论的内容,以及词语
amperometric在以下新条目的上下文中是如何使用的。
Artificial Neurons That Work Like Real Ones to Treat Neurological …
... defined as chemical-to-electrical-to-chemical signal transduction, is achieved by connecting enzyme-based amperometric biosensors and ... «Medgadget.com, 六月 15»
Swedish Scientists Build Artificial Neurons Able to Communicate …
... defined as chemical-to-electrical-to-chemical signal transduction, is achieved by connecting enzyme-based amperometric biosensors and ... «Hacked, 六月 15»
Therapeutic antidepressant potential of a conjugated siRNA …
5-HT concentrations were analyzed by high-performance liquid chromatography amperometric detection (+0.6V; Hewlett Packard 1049, Palo ... «Nature.com, 六月 15»
Nanosensors market segment forecasts up to 2020 shared in new …
The electrochemical transduction mechanism comprises amperometric or potentiometric among others. Whereas, the application area it is ... «WhaTech, 六月 15»
The positive effect on ketamine as a priming adjuvant in …
The voltage of the working electrode was set at +800 mV in the LC4C amperometric detector and the flow rate of the LC1150 HPLC pump was ... «Nature.com, 五月 15»
Platinum performance from crumpled sheets: Amperometric …
Platinum is the electrode material of choice for amperometric detection. This is because it is very good at promoting the oxidation and reduction ... «separationsNOW.com, 五月 15»
Acupuncture Point Microstructure Discovery
Another research team took amperometric oxygen microsensor readings and discovered that acupuncture points P7 and P6 demonstrate high ... «HealthCMi, 五月 15»
De-Chlorination Analyser Measures Near Zero Levels of Chlorine …
Conventional amperometric chlorine sensors are unstable when measuring near zero amounts of chlorine, which can lead to inaccurate and ... «International Environmental Technology, 四月 15»
Total Chlorine Analyser Simplifies Monitoring, Lowers Cost
Amperometric chlorine sensors are flow sensitive, the minimum required flow by the sensor is 0.5ft/sec, above this value the output is virtually ... «International Environmental Technology, 三月 15»
Oregon State University Researchers Turn to 3D Printing to Help …
stitutes of Health, titled “Fabrication of a Flexible Amperometric Glucose Sensor Using Additive Processes,” researchers look into the possibility ... «3DPrint.com, 三月 15»