与 «CRITICAL DAMPING»相关的英语书籍
在以下的参考文献中发现
critical damping的用法。与
critical damping相关的书籍以及同一来源的简短摘要提供其在 英语文献中的使用情境。
1
Manual of Numerical Methods in Concrete: Modelling and ...
... AT 10** ( 1.0) PER CENT STRAIN C C 15C. FRACTIONS OF CRITICAL
DAMPING, IN PER CENT - D FACTOR C11F5.3). C 1-5 FRACTION OF CRITICAL
DAMPING AT 10** (-4.0) PER CENT STRAIN C 6-10 FRACTION OF CRITICAL ...
Damping coefficient is defined as the damping force per unit velocity. Damping
factor £ is the ratio of the existing damping in a system to that required for critical
damping, i.e., £= c/cc. The frequency of an undamped system (f = o) depends ...
3
Reinforced Concrete Design of Tall Buildings
Damping is measured as a percentage of critical damping. In a dynamic system,
critical damping is defined as the minimum amount of damping necessary to
prevent oscillation altogether. To visualize critical damping, imagine a tensioned
...
Bungale S. Taranath, 2009
4
A Text Book of Theory of Machines
Ans. 1000 (it) Damping ctr-efficient of the dashpot in order to return the barrel to
the original position in the least time without oscillation, the dashpot should be
designed for critical damping. Hence the damping co-efficient of the dashpot
should ...
J. S. Brar, R. K. Bansal, 2004
13, the damping of the first mode of vibration was increased from less than 1
percent critical damping to 11 percent. Using similar methods, Preumont et al. [34
] have also increased critical damping in a truss from about 0.3 percent to 3.0 ...
6
Handbook of Optomechanical Engineering
The process of energy loss in a vibrating system is called damping. A system is
said to be critically damped if there is no vibration when the system is perturbed
from equilibrium. For a SDOF system, the critical damping coefficient Cc is given
...
7
Minimum Design Loads for Buildings and Other Structures
S1 isthemapped Figure 22-1 Maximum Considered Earthquake Ground Motion
For The Conterminous United States of 0.2 sec Spectral Response Acceleration (
5% of Critical Damping), Site Class B Figure 22-2 Maximum Considered ...
American Society of Civil Engineers, 2005
8
Motorcycle Handling and Chassis Design: The Art and Science
In this range more damping actually increases transmissibility and decreases
comfort, for example at a frequency ratio of 3 with no damping the transmission
ratio is 0.125 but increases to 0.608 at critical damping. This is logical because ...
9
Critical Damping in Complex Structures and Control Systems
This work examines the concept of critical damping normally defined for single degree of freedom systems as applied to more complex models of structures and their control systems.
D. J. Inman, STATE UNIV OF NEW YORK AT BUFFALO AMHERST DEPT OF MECHANICAL AND AEROSPACE ENGINEERING., 1984
10
Spar Platforms: Technology and Analysis Methods
Comparison of Maximum Allowable Heave Motion and Maximum Heave Motion
Varying with Heave and Pitch Damping Around Principle Zone 0% of Pitch 1% of
Pitch 5% of Pitch 10% of Pitch Critical Critical Critical Critical Damping Damping
...
包含词语«CRITICAL DAMPING»的新条目
找出国内和国际出版社所讨论的内容,以及词语
critical damping在以下新条目的上下文中是如何使用的。
Using torque to rotate an object into a desired orientation
If you choose parameters other than those that produce critical damping you'll still get overshoot. If you want to use torque, whatever scheme ... «GameDev.net, 一月 15»
America's Cup: Italians are ready to win
In addition the “jay” foiler's pitch and heave motion is poorly damped while the Moth height control gives near critical damping. While any yacht ... «Scuttlebutt Sailing News, 十月 14»
Dampers Show Flexibility in Retrofit of London's Millennium Bridge
... to elevate total structural damping levels to the 20% critical range, compared to approximately 0.5% critical damping for the as-built structure. «Design World Network, 二月 13»
Mordaunt-Short adds LCR and tower to Alumni home cinema …
Improved internal wadding gives support where needed, inherently strengthens the speaker and most importantly helps critical damping. Alumni 2 is Omnimount ... «eCoustics.com, 九月 08»