与 «HEMACYTOMETER»相关的英语书籍
在以下的参考文献中发现
hemacytometer的用法。与
hemacytometer相关的书籍以及同一来源的简短摘要提供其在 英语文献中的使用情境。
1
Basic Medical Laboratory Techniques
Manual cell counts are performed microscopically using the hemacytometer, a
special glass counting chamber. Hemacytometers are manufactured to meet the
specifications of the National Institute of Standards and Technology (NIST).
Barbara H. Estridge, Anna P. Reynolds, Norma J. Walters, 2000
2
Introduction to Cell and Tissue Culture: theory and technique
Use of a hemacytometer or an electronic particle counter gives the most direct
measurement of cell number and therefore cell growth. Cells can be counted
before, during, and after setting up an experiment to accurately and directly
quantitate ...
Jennie P. Mather, Penelope E. Roberts, 1998
3
Essential Laboratory Mathematics: Concepts and Applications ...
8.2 Manual Blood Cell Counts Cell enumeration using a hemacytometer is a
widely used method and continues to have a place in most laboratories,
including those that are now equipped with electronic cell counters. A good grasp
of basic ...
Catherine W. Johnson (MAed/Math.), Catherine W. Johnson, Daniel L. Timmons, 2003
4
Hematology: Clinical Principles and Applications
Maintaining steady pressure on the unit to prevent air bubbles, charge (fill) the
hemacytometer, and proceed with the count, as directed in procedure sections for
each type of count. Calculations The general formula for manual cell counts is as
...
5
Basic Clinical Laboratory Techniques
The hemacytometer is a precision-made slide for performing manual cell counts
using the microscope. The hemacytometer is sometimes called a counting
chamber. The hemacytometer counting chamber contains two microscopic ruled
areas ...
Barbara Estridge, Anna Reynolds, 2011
6
Manual of Exotic Pet Practice
Manual CBCs are commonly estimated using a hemacytometer (Figure 8-29)
with the Unopette® Eosinophil Determination for Manual Methods stain (Becton
Dickinson and Company, Franklin Lakes, NJ). A stained blood smear is also
needed ...
Mark A. Mitchell, Thomas N. Tully, 2009
7
Design, Operation and Training Manual for an Intensive ...
The authors prefer the "New Improved Neubauer" hemacytometer because there
is a depression on the bottom of the hemacytometer in the corresponding area of
the counting chamber that helps keep scratches from occurringon the glass.
Granvil D. Treece, Joe M. Fox, 1999
8
Human Stem Cell Technology and Biology: A Research Guide and ...
CELL COUNTING USING A HEMACYTOMETER NOTES Many cell culture
methods, such as cryopreservation, require an accurate determination of the
number of cells in a culture. The simplest and most readily available method for
cell ...
Gary S. Stein, Maria Borowski, Mai X. Luong, 2011
9
Pathology & Parasitology for Veterinary Technicians
The manual Unopette hemacytometer method of counting WBCs is the leukocyte
test most commonly used in veterinary hospitals. Unopette WBC test kits contain
diluting reservoirs and capillary pipettes for making a 1:100 dilution of blood in ...
10
Physical Removal of Giardia & CryptosporidiumSized Particles ...
Count/mL First Challenge Event Method (Mean±S.D) Filtered (Mean±S.D) No
headloss Hemacytometer 1, 1, 2, 1 (1.2±0.5) 0.3 x 104 Midpoint Hemacytometer
11,4,6,8(7.2±3) 1.8 x 104 Stop/Start ¤ Membrane filter 70 120 mL 0.6 90%
headloss ...
包含词语«HEMACYTOMETER»的新条目
找出国内和国际出版社所讨论的内容,以及词语
hemacytometer在以下新条目的上下文中是如何使用的。
Identification of novel drugs to target dormant micrometastases
CD44v3highALDH1high cells dissociated from spheres were counted by hemacytometer and replated to generate spheres of next generation. «BMC Blogs Network, 五月 15»
Transcriptome changes in Fusarium verticillioides caused by …
Conidial number was determined with a hemacytometer [47]. Macroconidia and microconidia were recorded as the number of conidia per ... «BMC Blogs Network, 四月 15»
Inorganic Arsenic-induced cellular transformation is coupled with …
Viable cells were counted weekly by trypan blue staining using a hemacytometer. Population doublings were calculated by the formula log ... «BMC Blogs Network, 三月 15»
Automated Measurements of Whole Blood and White Blood Cell …
There are a number of laboratories which still employ the standard and manual hemacytometer technique to measure the concentration and ... «News-Medical.net, 十一月 14»
Analysing Yeast Using the Vi-CELL™ XR
The manual method uses a microscope and hemacytometer and requires technicians to determine both unstained and stained and also to ... «Azom.com, 九月 14»
Estate Sale Roundup: July 31-August 3: You could be swimming …
... Bright-Line hemacytometer; American Dynaclave sterlizer; sphygmomanometer; hemometer; hemostats; and more. Furniture includes a 1955 ... «Austin Chronicle, 七月 14»
BIOPROCESS MONITORING: Photonics takes a new look at …
... by counting cells manually with a light microscope and a clicker-counter, while for VCD a light microscope and a hemacytometer was used. «Laser Focus world, 八月 11»
A human cell model for dynamic testing of MR contrast agents
Cell density and viability counts were made via trypan blue staining on a hemacytometer (Fisher Scientific, Ottawa, ON, Canada), and used to inform subsequent ... «BioTechniques.com, 二月 11»
Improved_cell_counting_technology
For years, cell counts in life science research laboratories have been performed using a light microscope and hemacytometer. This method is ... «Scientist Live, 五月 10»