与 «UNREINFORCED»相关的英语书籍
在以下的参考文献中发现
unreinforced的用法。与
unreinforced相关的书籍以及同一来源的简短摘要提供其在 英语文献中的使用情境。
1
Residential Remodeling Cost Estimator 2013 Edition
Concrete Wall, Sectional Forms, Unreinforced (cont.) V No footing or excavation
included in price. Description Unit Direct Labor Direct Materials Direct Total
Selling Price Manhours CONCRETE WALL BY CHUTE, UNREINFORCED, 12"
THICK ...
2
The ShakeOut Scenario Supplemental Study:
Unreinforced ...
Impacts of a M7.8 Southern San Andreas Earthquake on Unreinforced Masonry (
URM) Buildings Richard L. Hess, S.E. I Past Performance of URM Buildings:(1)
Unreinforced masonry (URM) bearing wall buildings have shown poor ...
3
Evaluation of Earthquake Damaged Concrete and Masonry Wall ...
ABK, 1981a, Methodology for Mitigation of Seismic Hazards in Existing
Unreinforced Masonry Buildings: Categorization of Buildings, A Joint Venture of
Agbabian Associates, S.B. Barnes and Associates, and Kariotis and Associates (
ABK), ...
Federal Emergency Management Agency
4
Simplified Design of Building Foundations
As with the wall footing, it is possible to use an unreinforced footing as long as
stresses in the concrete are low. Table 3.4 gives sizes for unreinforced column
footings for a range of soil pressure and two concrete strengths. The maximum
size ...
5
Handbook for Blast Resistant Design of Buildings
c16 JWBT157/Dusenberry November 18, 2009 11:26 Printer Name: Yet to Come
UNREINFORCED MASONRY 439 it is necessary to provide sufficient support to
allow masonry walls to develop full plastic mechanism. This can be achieved by ...
Donald O. Dusenberry, 2010
6
Unreinforced Responding During Limited Access to Intravenous ...
We explored changes that occur during the acquisition of heroin self-administration in rats.
Erin Lynn Cummins, University of Guelph. Department of Psychology, University of Guelph. School of Graduate Studies, 2008
7
Seismic Strengthening of Low-rise
Unreinforced Masonry ...
Based on the experimental results, the model implied by the "Prestandard for the Rehabilitation of Existing Structures", FEMA 356, for the analysis of in-plane URM walls was modified and extended to (1) include the effect of FRP pier ...
8
Building Code Requirements for Masonry Structures (ACI ...
1.14.2.2.2 Detailed plain (unreinforced) masonry shear walls — These shear
walls are designed as plain (unreinforced)) masonry per the sections noted, but
contain minimum reinforcement in the horizontal and vertical directions. Because
of ...
9
Handbook of Molded Part Shrinkage and Warpage
Table 11.7 Nominal Thermoplastic Mold Shrinkage Rates Using ASTM Test
Specimens5 Material Reinforcement Average ratea per ASTM D955 0.125 inch (
3.18 mm) 0.250 inch (6.35 mm) ABS Unreinforced 0.004 0.007 30% glass fiber
0.001 ...
10
Total Quality Process Control for Injection Molding
Average Rate per ASTM D-955 Directional Rates 0.062 Inch Sample Material
0.125 inch 0.250 inch Flow Transverse ABS unreinforced 0.004 0.007 0.005
0.005 30% glass fiber 0.001 0.0015 0.001 0.002 Acetal, copoly unreinforced
0.017 ...
M. Joseph Gordon, Jr., 2010
包含词语«UNREINFORCED»的新条目
找出国内和国际出版社所讨论的内容,以及词语
unreinforced在以下新条目的上下文中是如何使用的。
Christchurch council calls for tighter rules for earthquake-prone …
The unreinforced masonry issue was a key point in the council's original submission made to the select committee in 2014 and also that of Ann Brower, the sole ... «The Press, 七月 15»
LA Shares Quake Vulnerabilities With Kathmandu
The 1933 Long Beach quake exposed the seismic weakness of unreinforced brick buildings. All of the brick buildings have now been reinforced in Los Angeles, ... «NBC Southern California, 四月 15»
City beginning to crack down on owners of unreinforced masonry
The Martinez City Council adopted an ordinance in 2009, mandating the seismic retrofitting of all high-risk unreinforced masonry (URM) buildings within six ... «Martinez News-Gazette, 一月 15»
Martinez: Deadline approaching for retrofit of unreinforced brick …
MARTINEZ -- There are still 14 unreinforced brick buildings in downtown Martinez that present a seismic safety hazard. The city adopted a mandatory ... «Contra Costa Times, 十二月 14»
Momentum slows on fixing S.F's dangerous brick buildings
But a small number of those unreinforced brick buildings — 29 buildings clustered at 19 sites — never met that deadline and still could be dangerous, especially ... «SFGate, 十月 14»
Quake retrofit scofflaws ignore compliance at public's peril, officials say
By August 2011, Napa officials required owners of 10 unreinforced masonry ... The city meets twice a month to help owners of its 17 unreinforced masonry ... «San Jose Mercury News, 九月 14»
Experimental study on dynamic behavior of unreinforced masonry …
... of Engineering in Peru and Building Research Institute-conducted shaking table tests to investigate the dynamic behavior of unreinforced masonry walls. «Phys.Org, 九月 14»
Often overlooked, brick chimneys pose hazards in quakes
Although brick chimneys have received little attention from seismic safety experts — overshadowed by more life-threatening issues such as unreinforced ... «Los Angeles Times, 九月 14»
Buildings at risk: About 170 still standing in Sonoma County
There are 7,800 of these structures — officially dubbed unreinforced masonry buildings, or URMs — in 29 counties, and they are at “significant risk of collapse,” ... «Santa Rosa Press Democrat, 九月 14»
Napa earthquake a 'wake up call' for owners of unreinforced masonry
The Martinez City Council adopted an ordinance in 2009, mandating the seismic retrofitting of all high-risk unreinforced masonry (URM) buildings within six ... «Martinez News-Gazette, 八月 14»