«ELECTROGRAM»に関連する英語の本
以下の図書目録から
electrogramの使いかたを見つけましょう。
electrogramに関する本と英語文献で使われた文脈を提供するための簡単な抜粋文。
1
Clinical Arrhythmology and Electrophysiology: A Companion to ...
CH 22 VT entrainment from entrance of the critical isthmus RVA Hisprox Abldist
Ablprox S S S PCL 480 msec VT CL 495 msec False PPI 360 msec True PPI 495
msec EGM-QRS 310 msec FIGURE 22-26 Using the proximal electrogram ...
Ziad Issa, John M. Miller, Douglas P. Zipes, 2012
2
Arrhythmia: New Insights for the Healthcare Professional: ...
“Although occasionally described as an electrocardiogram (ECG), the electrical
signal from the heart as measured from electrodes within the body is properly
termed an 'electrogram' or intramyocardial electrogram (IMEG). For the purpose
of ...
3
Clinical Cardiac Electrophysiology: Techniques and ...
The stimulus to QRS and return cycle also are nearly identical to the electrogram
to QRS during a tachycardia and VT cycle length. B: RF application at this site
terminates the tachycardia in 3.5 seconds. Following ablation, the tachycardia
was ...
4
Mayo Clinic Electrophysiology Manual
A. A PAC placed from the distal coronary sinus advances the ventricular
electrogram without changing the QRS morphology and without advancing the
atrial electro- gram on the His bundle catheter. The advanced ven- tricular
electrogram in ...
Samuel J. Asirvatham, Yong-Mei Cha, Paul A. Friedman, 2013
5
Handbook of Cardiac Electrophysiology: A Practical Guide to ...
2.1C THE AH INTERVAL 2.1D THE DURATION OF THE HIS BUNDLE
ELECTROGRAM The AH interval is the time taken for the cardiac impulse to
travel over the atrioventricular (AV) node, and is measured from the electrograms
recorded by ...
6
The Nuts and Bolts of ICD Therapy
L' 3 It is also possible to adjust the 'dynamic range' for stored electrogram signals.
Intrinsic cardiac activity is stored in the device memory for subsequent retrieval. In
order to compress and store this sort of data, it is sometimes necessary to ...
7
Catheter Ablation of Cardiac Arrhythmias: Expert Consult
Five electrogram characteristics have been described as use- ful in predicting
successful ablation sites when mapping antegrade AP activation by the
transaortic approach: (1) delta-to-ventricle (V) interval, (2) atrial electrogram
amplitude, ...
Shoei K. Stephen Huang, Mark A. Wood, John M. Miller, 2010
The duration of the atrial electrogram was measured from the earliest atrial
activation site to the latest atrial activation site from a stable baseline. The signal
information from the mapping catheter, including activation time, electrogram
voltage ...
Mohammad Shenasa, Gerhard Hindricks, Martin Borggrefe, 2012
9
Cardiac Electrophysiology: Clinical Case Review
The ventricular electrogram morphology discriminator (MDTM)1,2 was
programmed ON. This discriminator diagnoses SVT and withholds VT therapy if
five of eight ventricular electrograms in a sliding window have a match score of or
higher ...
Andrea Natale, Amin Al-Ahmad, Paul J. Wang, 2011
10
Cardiac Arrhythmias: New Insights for the Healthcare ...
about 5 Hz and about 10 Hz; presence of an isoelectric line; presence of a
complex potential, multicomponent; a peak-to-peak amplitude greater than about
1 mV; a slew rate between about 0.25 mv/s and about 1 mV/s; and an
electrogram ...
用語«ELECTROGRAM»を含むニュース項目
国内外の報道機関が語った内容や、次のニュース項目の文脈から
electrogramという用語がどのように使われているかを調べてみましょう。
Keegan Calmes from Vinyl Theatre talks new single and tour dates …
They worked closely with the record label for the song selection process of their album, Electrogram. "We had picked a lot of our older songs ... «Digital Journal, 7月 15»
The 405 meets Vinyl Theatre
Keegan: Yeah I think so, especially with our album Electrogram. The album definitely represents the live show in a way, and we couldn't ... «The 405, 5月 15»
CardioBreak: Mitra Clip, Ambulatory BP Apathy
A collaboration in atrial fibrillation diagnostics aims to use electrogram signal data from GE's CardioLab electrophysiology recording system ... «MedPage Today, 5月 15»
NEW STUDY EXAMINES PERFORMANCE OF THE WORLD'S …
Examination of 24 hour ambulatory surface ECG and device electrogram indicated expected pacing and sensing performance with no pauses ... «HealthCanal.com, 5月 15»
Miniaturized leadless transcatheter pacing system safe in first …
When the researchers examined 24-hour ambulatory surface ECG and device electrogram, they found expected sensing and pacing ... «Healio, 5月 15»
Stereotaxis to Present New Clinical Evidence and Product …
... Vein Isolation: Lessons From Bipolar Electrogram Morphology Analysis." In addition, use of Stereotaxis' Niobe system for VT procedures will ... «GlobeNewswire, 5月 15»
STAR AF 2: 'Less Is More' When Using Ablation to Treat Persistent …
They were randomized in a 1:4:4 design to receive PV alone (n= 67, 78% men) or with complex electrogram ablation (n=263, 81% men) or ... «Medscape, 5月 15»
Study: Three Ablation Techniques Get Similar Results
So did 125 patients of 244 who had isolation plus electrogram, and 132 of 244 patients who had isolation plus lines. Rates of the primary ... «MD Magazine, 5月 15»
Complex Ablation Not Better in Persistent Afib
The only death occurred in the isolation plus complex electrogram-ablation group. That case of procedure-related atrioesophageal fistula ... «MedPage Today, 5月 15»
Photos + Words | Smallpools with Grizfolk and Vinyl Theatre
... large handful of people in the crowd still knew all the words to their single, "Breaking Up My Bones" from their full-length record, Electrogram. «Speakers in Code, 5月 15»