与 «ELECTROOSMOTIC»相关的英语书籍
在以下的参考文献中发现
electroosmotic的用法。与
electroosmotic相关的书籍以及同一来源的简短摘要提供其在 英语文献中的使用情境。
1
Capillary Electrophoresis: Theory and Practice, Second Edition
They utilized both approaches in determining the zeta potential and
electroosmotic flow of Teflon capillaries as a function of pH. D. Alteration Of
Electroosmotic Flow A great deal of work has been done to manipulate
electroosmotic flow.
2
Capillary Electrophoresis: Principles, Practice and Applications
Ne: effactr Fig. 1.7. Migration order for cations (+), non-ions (0), and anions (—)
based on the cumulative effects of electrophoresis and strong electroosmotic fiow
toward the cathode. (Reproduced from Ref. 11 with permission of Marcel Dekker,
...
3
Application of
Electroosmotic Pumps to Low Temperature Fuel ...
Chapter 2: Water Management in Proton Exchange Membrane Fuel Cells using
Integrated Electroosmotic Pumping The content of this chapter was originally
published by Buie et al.111 and is presented here with minor modifications.
Cullen Richard Buie, 2009
4
Handbook of Capillary Electrophoresis, Second Edition
Role of Electroosmotic Flow in CE Analysis Electroosmotic flow was first
identified in the late 1800s when Helmholtz81 conducted experiments involving
the application of an electrical field to a horizontal glass tube containing an
aqueous salt ...
5
New Trends in Fluid Mechanics Research: Proceedings of the ...
The coupled Poisson-Boltzmann equation, Laplace equation, and modified
Navier-Stokes equation are solved by finite volume method to describe
distribution of electroosmotic flow. The detailed numerical results show that the
salt ...
F. G. Zhuang, J. C. Li, 2009
6
Remediation of Hazardous Waste Contaminated Soils
15 The phenomenon was first treated analytically by Helmholtz.16 and later it
was modified by Pellat17 and Smoluchowski.18 This theory is widely known as
Helmholtz-Smoluchowski (H-S) theory. which deals with electroosmotic velocity
of a ...
7
Microsystem Engineering of Lab-on-a-chip Devices
Written on a non-specialist level by an interdisciplinary team of chemists, biologists and engineers from one of Europe's leading centres for microsystem research, the Danish Mikroelektronik Centret (MIC), this is a concise practical ...
Oliver Geschke, Henning Klank, Pieter Telleman, 2006
8
Electrokinetics in Microfluidics
7-8 JOULE HEATING EFFECTS ON ELECTROOSMOTIC FLOW As discussed
previously, while electrokinetically driven transport processes have great
advantages in the flow control and species transport in microfluidic devices, there
exists ...
9
Electrochemical Remediation Technologies for Polluted Soils, ...
6. 0°. 01'. 9T. Z. °. of“. = 0 O — e a E 2'0 i g We .e -4.0- 0 - O o O E Q 1 l 1 l 1 l 1 l 1
l 0.0 100.0 200.0 300.0 400.0 500.0 Treatment time (h) Figure 3.7. Variation of
electroosmotic volume rate with time. The direction of electroosmotic flow can be
...
Krishna R. Reddy, Claudio Cameselle, 2009
10
Handbook of Capillary and Microchip Electrophoresis and ...
Two noninvasive methods of temperature measurement based on the
electroosmotic mobility and conductance are discussed in further detail below.
The linear relationships between both the electroosmotic mobility and the
conductance ...
包含词语«ELECTROOSMOTIC»的新条目
找出国内和国际出版社所讨论的内容,以及词语
electroosmotic在以下新条目的上下文中是如何使用的。
Conical nanopores rectify electroosmotic flows
Pablo Alonso describes how a scanned probe can be used for sensing and imaging beyond the diffraction limit. Click to view ... «nanotechweb.org, 六月 15»
Genotyping Using CGE
To mitigate electroosmotic flow (EO) and prevent analyte adhesion to the inside walls of the capillary column, they are dynamically coated with ... «Genetic Engineering & Biotechnology News, 四月 15»
Creating Plug-Like and Parabolic Flow Profiles in a Microfluidic …
Flow profile in an open microfluidic channel. (A) Hydrodynamic flow with parabolic profile and (B) Electroosmotic flow with plug-like flow profile. «News-Medical.net, 四月 15»
UNK sends 27 to national conference
“Determination of Electroosmotic and Electrophoretic Forces in a Gel Matrix in Different Ionic Strength Conditions.” Dr. Kristy Kounovsky-Shafer, ... «Unkantelope, 四月 15»
Behind the dogmas of good old hydrodynamics
... conducted by the professor of the Moscow University Ferdinand Friedrich Reuss in 1807, which helped to discover the electroosmotic flow. «Phys.Org, 三月 15»
Porous poking: Ultra-fast protein analysis with CE-MS
Because Moini's system has the far end of the capillary open to the air, running the electroosmotic flow in the opposite direction simply drains ... «separationsNOW.com, 一月 14»
Nanocrystalline Silicon Membranes Help Shrink the Power Source …
Electroosmotic pumps (EOPs), devices in which fluids appear to magically move through porous media in the presence of an electric field, are ... «AZoNano.com, 十月 13»
Researchers measure flow from a nanoscale fluid jet
The researchers applied an electric voltage across the capillary, which was submerged in a salt solution to create an electroosmotic flow that ... «Phys.Org, 十月 13»
Single-molecule nanopore research made easy
"Interestingly, in our experimental conditions, electrophoresis dominates over electroosmotic effects in determining the direction of translocation ... «Nanowerk, 五月 13»
Controlling particles for directed self-assembly of colloidal crystals
When these forces are low enough, electrophoretic-electroosmotic flows induced by applying a DC field allow the researchers to selectively ... «Phys.Org, 一月 13»