MOTS EN ANGLAIS EN RAPPORT AVEC «HYPERACUITY»
hyperacuity ·
hearing ·
hyperacuity ·
medical ·
more ·
from ·
merriam ·
webster ·
greater ·
than ·
normal ·
acuteness ·
especially ·
sense ·
specifically ·
visual ·
acuity ·
that ·
better ·
twenty ·
compare ·
grating ·
stereoacuity ·
vernier ·
michael ·
bach ·
note ·
this ·
requires ·
little ·
patience ·
what ·
neighbouring ·
interactive ·
demo ·
shows ·
left ·
lines ·
atop ·
each ·
other ·
with ·
slight ·
sensation ·
perception ·
these ·
represent ·
just ·
examples ·
class ·
tasks ·
were ·
given ·
label ·
gerald ·
westheimer ·
have ·
common ·
scholarpedia ·
many ·
discrimination ·
abilities ·
which ·
human ·
observer ·
surpasses ·
limit ·
often ·
large ·
factor ·
called ·
define ·
sharpness ·
10 LIVRES EN ANGLAIS EN RAPPORT AVEC «HYPERACUITY»
Découvrez l'usage de
hyperacuity dans la sélection bibliographique suivante. Des livres en rapport avec
hyperacuity et de courts extraits de ceux-ci pour replacer dans son contexte son utilisation littéraire.
Hyperacuity There is a third kind of measure of sensitivity to spatial variations,
which bears a superficial resemblance to the measures of sensitivity to spatial
separation (such as the two-point threshold) just described. However, since in
these ...
Russell L. DeValois, Berkeley Karen K. DeValois both Professors of Psychology University of California,
1988
2
Computational Neuroscience: Trends in Research 2000: Trends ...
J. 70 (1996) 2513—2526. [6] Y. Kashimori, T. Kambara, A neural mechanism for
hyperacuity in jamming avoidance response of electric fish Eigenmannia,
Proceedings of 1997 IEEE International Conference on Neural Networks Vol. 1,
1997 ...
3
Strabismus and Amblyopia: Experimental Basis for Advances in ...
For this reason, Westheimer (1975) has coined the term "hyperacuity" to describe
a variety of tasks that involve sensing the direction of spatial offset of a line or
point relative to a reference. This performance is remarkable considering that
even ...
Gunnar Lennerstrand, Gunter K. Von Noorden, Emilio C. Campos,
1988
4
Frontiers of Visual Science: Proceedings of the 1985 Symposium
Within the last few years, several authors have offered theoretical explanations
for hyperacuity performance in terms of the properties of spatial filtering in the
visual system (Wilson and Gelb, 1984; Carlson and Klopfenstein, 1985).
5
Digital Color Halftoning
10.2.6 HYPERACUITY There is one more complexity: human vision is very
sensitive to edge sharpness. Sometimes human vision requires the placement of
edges 10 to 60 times more accurately than that indicated by frequency responses
[28] ...
6
Clinical Ophthalmology: Contemporary Perspectives
Hyperacuity. When clinically assessed, the acuity is referred to in terms of
Snellen's acuity. However, the visual system is capable of finer spatial
discrimination such as relative position, size and orientation, the appreciation of
which has been ...
7
Computational Models of Visual Processing
These themes will be elucidated through the application of pattern discrimination
models to hyperacuity, curvature, and spatial frequency discrimination tasks.
Local and Global Processing in Hyperacuity Hyperacuity is the name coined by ...
Michael S. Landy, J. Anthony Movshon,
1991
8
Perimetry Update 1994/1995: Proceedings of the XIth ...
For hyperacuity assessment, the first gap setting examined is 1 octave larger than
the best measured Gap "VA" determination. Vernier acuity response is tested
twice at this setting. Then, the gaps are set 1 octave smaller and the Vernier
acuity ...
Richard P. Mills, Michael Wall,
1995
Though the photoreceptor response in M. domestica is Gaussianshaped,
hyperacuity may also be achieved with other continuous, nonlinear functions.
Luke et al. studied the requirements for motion hyperacuity in detail. Motion
hyperacuity is ...
Akhlesh Lakhtakia, Raul Jose Martin-Palma,
2013
10
Level of Detail for 3D Graphics
The question therefore arises: need we account for hyperacuity in a perceptual
model for guiding LOD? It is believed that hyperacuity is caused by differences in
the mean distribution of light sampled over a number of photoreceptors [Morgan ...
David Luebke, Martin Reddy, Jonathan D. Cohen,
2002
10 ACTUALITÉS CONTENANT LE TERME «HYPERACUITY»
Découvrez de quoi on parle dans les médias nationaux et internationaux et comment le terme
hyperacuity est employé dans le contexte des actualités suivantes.
Multi-use technology symposium is Thursday
After introductions, the first speakers of the day will be Duncan Stewart, Lamina Systems, and Jeff Radke, Honeywell Corporation, “Hyperacuity ... «Ridgecrest Daily Independent, juil 15»
New mVT® Research Shows Significant Value for AMD and DR …
The last study, also supported by NIH, investigated the strength of the shape discrimination hyperacuity test methodology of the mVT. Results ... «Digital Journal, juin 15»
Home monitoring enables early detection of CNV in AMD patients
ForseeHome is a hyperacuity visual field test in which signals are presented within the central visual field and patients report perceived image ... «Healio, janv 15»
New NEI Study Finds Patients at High-Risk for Developing …
The ForeseeHome AMD Monitoring Program utilizes a simple to use device based on preferential hyperacuity perimetry, a form of macular-field ... «VentureBeat, nov 13»
NIH Study Finds Patients at High-Risk for Developing Neovascular …
The ForeseeHome AMD Monitoring Program utilizes a simple to use device based on preferential hyperacuity perimetry, a form of visual-field ... «Business Wire, nov 13»
Rudolf Kingslake Medal Awarded by SPIE for TNO Paper on Color …
... he worked on visual spatial localization (hyperacuity) and image processing. At TNO, he investigates multimodal image fusion, image quality, ... «PR Web, sept 13»
FDA-cleared eye app raises $500K, seeks pharma partnership
The company's flagship product, myVisionTrack, is an iPhone 4S-based shape discrimination hyperacuity test for patients with serious ... «mobihealthnews, août 13»
Notal Vision Awarded 2013 Arch Grant
The ForeseeHome utilizes a proprietary technology platform called Preferential Hyperacuity Perimetry. Patients complete a short test on their ... «PR Web, mai 13»
iPhone App for Vision Tests Gains FDA Approval
It incorporates a proprietary shape discrimination hyperacuity (SDH) test by the Retina Foundation of the Southwest, which developed an eye ... «eWeek, avril 13»
FDA clears iPhone vision test
The app runs a test called shape discrimination hyperacuity (SDH), which is licensed from the Retina Foundation of the Southwest, whose ... «mobihealthnews, avril 13»