«CONTACTOR»に関連するポルトガル語の本
以下の図書目録から
contactorの使いかたを見つけましょう。
contactorに関する本とポルトガル語文献で使われた文脈を提供するための簡単な抜粋文。
1
Refrigeration & Air Conditioning Technology
OBJECTIVES After studying this unit, you should be able to • describe the
differences between a relay, a contactor, and a starter. • state how the locked-
rotor current of a motor affects the choice of a motor starter. • list the basic
components of a ...
William C. Whitman, William M. Johnson, John A. Tomczyk, 2005
2
Commercial Refrigeration for Air Conditioning Technicians
The thermostat, high-pressure, and low-pressure controls are wired in series with
the contactor coil. To stop a 30 motor, all three power wires must be opened at
the same time. Single-phase compressors only need one of the two power legs ...
3
Oilfield Processing of Petroleum: Natural gas
It should be located as close as possible to the amine contactor. It can be
complemented, but not replaced, by an integral scrubber in the contact tower.
Removal of contaminants from the inlet gas is enhanced by washing the gas with
water.
Francis S. Manning, Richard E. Thompson (Ph.D.), 1991
4
Handbook of Electric Motors
When the start button is pressed, contactor M picks up, latching itself in by means
of auxiliary contacts M,, and connecting the motor circuit to the line by main
contacts M. Contactor 1A is the accelerating contactor. At start, the only voltage ...
Hamid A. Toliyat, Gerald B. Kliman, 2012
Once he determined that line voltage was being supplied to the unit, the next
logical step was to check for low voltage; but, William first checked to make
certain that voltage was present on the line side of the cooling contactor. This is
not ...
6
Practical Troubleshooting of Electrical Equipment and ...
The power circuit consists of a three-phase mains supply with a fuse unit, three
contactors – line contactor, star contactor, and delta contactor. The line contactor
gets its three-phase power supply from the fuse unit and the output terminals of ...
Mark Brown, Jawahar Rawtani, Dinesh Patil, 2004
7
Industrial Motor Control
The field contactor looks very similar to a common three—pole contactor (Figure
45-5). This is not a standard contactor, however. The field contactor contains a
DC coil and is energized by the excita— tion current of the rotor. The field
contactor ...
8
Commercial Electrical Wiring
An auxiliary contactor (C4) is connected in series with the stop pushbutton and in
parallel with the start pushbutton. The control circuit also has normally closed
overload contactors (OC) connected in series with the magnetic starter coil (C).
John E. Traister, Ronald T. Murray, 2000
9
Standard Handbook of Petroleum & Natural Gas Engineering
The wet gas leaves the top of the inlet scrubber and passes to the vertical glycol-
gas contactor. The gas enters the bottom of this vessel and flows upward through
the contact medium countercurrent to the glycol flow. The contact medium in the ...
10
Practical Variable Speed Drives and Power Electronics
In addition, closing the motor side contactor when converter output voltage is
present can result in a motor inrush current similar to DOL starting. Apart from the
stress this places on the converter, the drive will trip on over-current. Repeated ...
用語«CONTACTOR»を含むニュース項目
国内外の報道機関が語った内容や、次のニュース項目の文脈から
contactorという用語がどのように使われているかを調べてみましょう。
ABB Selects Solvay's Technyl One for New Contactor Application
Targeted applications include miniature circuit breakers (MCBs), moulded case circuit breaker (MCCB) and contactor parts requiring high amperage and thermal ... «NETCOMPOSITES, 10月 15»
$500 a day: Contactor on Branson project pays for delays with …
The first phase of downtown Branson's streetscape was supposed to have been done last summer. But, by the looks of the construction cones and gravel ... «KY3, 10月 15»
Washington Sues Contactor Building $3.1B Seattle Tunnel
Washington is suing the contractor building the $3.1 billion tunnel replacement project for Seattle's Alaskan Way Viaduct. In a statement late Friday afternoon, ... «Insurance Journal, 10月 15»
State of Washington sues contactor building Seattle tunnel
SEATTLE (AP) - The state of Washington is suing the contractor building the $3.1 billion tunnel replacement project for Seattle's Alaskan Way Viaduct. «KHQ Right Now, 10月 15»
Aehr Test Systems Announces First Order for New FOX-XP(TM …
This first FOX-XP engineering system and several WaferPak Contactors will be used for reliability and qualification test of devices intended for a very high ... «GlobeNewswire, 10月 15»
Yamaichi Electronics 0.35mm pitch test contactor for semiconductor …
For testing such devices, Yamaichi Electronics in Europe (European headquarters in Munich, Bavaria) develops test contactors (TC) within the YED254 and ... «ElectroIQ, 10月 15»
Research delivers insight into China's low voltage circuit breaker …
China Low Voltage Contactor Industry 2015. China Low Voltage Contactor Industry is an accurate and quality research study on the China Low Voltage ... «WhaTech, 9月 15»
Vacuum Contactor Market by Voltage, by Application, by End-user …
LONDON, Sept. 14, 2015 /PRNewswire/ -- This report estimates the vacuum contactor market in terms of value in USD million. The overall vacuum contactor ... «PR Newswire, 9月 15»
Lightweight contactors handle inrush currents up to 4000 AMPS
TE Connectivity's new KILOVAC KHR500 (Bubba II) high-voltage, high-rupture, 600 AMP contactor is smaller, lighter, and switches significantly higher power ... «Engineer Live, 8月 15»
Research and Markets: Vacuum Contactor Market to 2020 - The …
In the methodology various secondary sources have been used such as encyclopedias, directories, and databases to identify and collect information that was ... «Business Wire, 8月 15»